Scania TMS fault codes
All 1.000 Scania TMS (Transmission Management System) diagnostic trouble codes, with meaning, causes and how to fix them.
Control units:
TMS1TMS2 (TMS)TMS3 (TMS)TMS4 (TMS)TMS5 (TMS)TMS6 (TMS)TMSe2 (TMS)
Showing 841–900 of 1.000 codes
- 21022hex 521E ABS
- 21025hex 5221 CAN communication from AWD system
- 21026hex 5222 Transfer gearbox
- 21030hex 5226 Temperature sensor for coolant
- 21040hex 5230 Temperature sensor for retarder oil
- 22000hex 55F0 Temperature sensor for coolant
- 22001hex 55F1 Temperature sensor for coolant
- 22010hex 55FA Oil temperature sensor
- 22011hex 55FB Oil temperature sensor
- 24000hex 5DC0 Oil pressure
- 24001hex 5DC1 Oil pressure
- 27000hex 6978 Solenoid valve for activation of retarder
- 27001hex 6979 Solenoid valve for activation of retarder
- 27002hex 697A Solenoid valve for activation of retarder
- 27010hex 6982 Solenoid valve for retarder oil accumulator
- 27011hex 6983 Solenoid valve for retarder oil accumulator
- 27012hex 6984 Solenoid valve for retarder oil accumulator
- 27100hex 69DC Proportional valve
- 27101hex 69DD Proportional valve
- 27102hex 69DE Proportional valve
- 27200hex 6A40 Valve block with proportional valve V97
- 27201hex 6A41 Proportional valve
- 28673hex 7001 The synchromesh actuating arm remains immobile in the disengaged position
- 28674hex 7002 The synchromesh actuating arm is not engaged, instead it returns to the disengaged position during deactivation.
- 28675hex 7003 The synchromesh actuating arm gets stuck during engagement and does not return to the disengaged position.
- 28676hex 7004 The synchromesh actuating arm cannot be engaged.
- 28677hex 7005 The synchromesh actuating arm is disengaged when the solenoid valve is activated
- 28678hex 7006 Retarder oil pressure
- 28929hex 7101 The synchromesh actuating arm remains immobile in the engaged position
- 28930hex 7102 The synchromesh actuating arm does not reach the disengaged position
- 29185hex 7201 Long disengagement time for freewheeling retarder
- 29186hex 7202 The synchromesh actuating arm cannot be engaged.
- 29187hex 7203 The synchromesh actuating arm cannot be disengaged
- 29188hex 7204 Freewheeling retarder
- 29952hex 7500 Open circuit in solenoid valve for operating the freewheeling retarder.
- 29953hex 7501 Solenoid valve for operating freewheeling retarder
- 29954hex 7502 Solenoid valve for operating freewheeling retarder
- 30208hex 7600 Freewheeling retarder position sensor is short-circuited to ground
- 30209hex 7601 Position sensor for freewheeling retarder
- 30210hex 7602 There is an internal fault in the freewheeling retarder position sensor
- 30211hex 7603 There are incorrect voltage levels in the freewheeling retarder position sensor
- 37103hex 90EF Articulation control system, communication error
- 37104hex 90F0 Articulation control system, fault in CAN message
- 37105hex 90F1 Articulation control system, fault in CAN message
- 45057hex B001 A fault code has been set in the Allison GMS control unit A5
- 49511hex C167 Time-out during immobiliser validation
- 49958hex C326 Immobiliser
- 50000hex C350 ECA unit
- 50010hex C35A ECA unit
- 50020hex C364 ECA unit
- 50040hex C378 ECA unit
- 50050hex C382 ECA unit
- 50060hex C38C ECA unit
- 50070hex C396 ECA unit
- 50080hex C3A0 ECA unit
- 50090hex C3AA ECA unit
- 50100hex C3B4 ECA unit
- 50110hex C3BE ECA unit
- 50140hex C3DC Overheated clutch
- 50141hex C3DD Worn clutch